FixVault

DTC U2300-64: Instrument Cluster Configuration Error (Blind Spot Monitoring System): Notes

DTC U2300:64 (BLIND SPOT MONITORING SYSTEM) DETECTION CONDITION AND POSSIBLE CAUSE

Description Instrument cluster configuration error
Detection condition
  • Instrument cluster configuration error (signal error) detected with the ignition switched ON (engine off or on).
Fail-safe
  • Blind spot monitoring (BSM) system is stopped.
Possible cause
  • Instrument cluster configuration error
  • Blind spot monitoring (BSM) control module (LH) malfunction
System wiring diagram Not applicable