FixVault

A/F Sensor Heater Inspection

CAUTION:
  • Do not allow flammable objects such as the taping for bundling a wiring harness to come into contact with the exhaust manifold and silencer.
  1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  2. Disconnect the A/F sensor connector. (See AIR FUEL RATIO (A/F) SENSOR REMOVAL/INSTALLATION .)
  3. Measure the resistance between A/F sensor terminals A and E.
    G11427340Courtesy of MAZDA MOTORS CORP.

    A/F sensor heater resistance 

    1-10 ohms [normal temperature]