Refrigerant Charging: Evacuation

WARNING: This page is about a different car, the 2017 Mazda 3. However, it is still accessible from the selected car via links, so may be relevant.
  1. Open all the valves of the manifold gauge.
    • Close the manifold gauge valve immediately after stopping the vacuum pump. If the valve is left open, the vacuum pump oil will back flow into the refrigeration cycle and cause a decrease in the efficiency of the air conditioner.
  2. Start the vacuum pump and let it operate for 15 min.
    Fig 1: Starting Vacuum Pump
    G09075740Courtesy of MAZDA MOTORS CORP.
  3. Verify that high- and low-pressure side readings of the manifold gauge are at -101 kPa {-1.03 kgf/cm2 , -14.6 psi}. Close each valve of the manifold gauge.
Fig 2: Checking High And Low Pressure Side Readings Of Manifold Gauge - Evacuation
G09075741Courtesy of MAZDA MOTORS CORP.