FixVault

Power Window Subswitch Illumination Inspection

  1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION [(US)] .)
  2. Remove the power window subswitch. (See POWER WINDOW SUBSWITCH REMOVAL/INSTALLATION .)
  3. Apply battery positive voltage to power window subswitch terminal A, and connect terminal D to ground.
    G13178699Courtesy of MAZDA MOTORS CORP.
    B+ Terminal Ground Terminal Operation
    A D LED Turn On
  4. Verify that the LED is turned on.