FixVault

Shift-Lock Solenoid Inspection: Standard

TERMINAL VOLTAGE SPECIFICATIONS - STANDARD

Terminal Connected to Test condition Voltage (V)
A IG1 relay No. 2 Ignition switched ON (engine on) B+
Except above Below 1.0
E Shift panel indicator The following conditions are met (except emergency manual shift-lock release system is operated)
  • Selector lever is in P position
  • Ignition is switched to ON
  • Brake pedal is depressed (brake light switch is on)
Below 1.0
Except above B+