FixVault

Neutral Sensor Installation Note

  1. Clean neutral sensor and the neutral sensor installation hole.
    NOTE:
    • Do not apply manual transaxle oil to the O-ring.
  2. Apply manual transaxle oil to the neutral sensor installation hole.
  3. Install a new O-ring to neutral sensor.
  4. Install neutral sensor and the O-ring as a single unit.