Function inspection

NOTE:
  • Perform the procedure with the main power switched ON (READY off).
  1. Display the PIDs [TP1] and [TP2]. (Refer to [PID/DATA MONITOR INSPECTION ] in the appropriate troubleshooting information )
  2. Compare the voltage and opening angle indications for PIDs [TP1] and [TP2] with the standard in the table indicated below.

Standard 

STANDARD TP1 SPECIFICATIONS

Condition TP1 TP2
V % V %
Accelerator pedal released Approx. 1.11 Approx. 22 Approx. 3.92 Approx. 22
Accelerator pedal depressed Approx. 4.59 Approx. 92 Approx. 0.41 Approx. 92