Hydraulic Oil Pump
- Check oil level in reservoir, fill if necessary. Disconnect pressure hose from pressure line (to level control valve) at rear connection. Connect special 3-way valve (Mercedes-Benz tool 038o) with pressure gauge (Mercedes-Benz tool 038a) to pressure hose. Place a graduated container under 3-way valve.