ADAPTOR Cable For Compression Pressure Recorder (58/68)
Publication date: 1988-12-01Reference number: 58/68
Supersedes refnos: 15/37
ADAPTOR CABLE FOR COMPRESSION PRESSURE RECORDER
TECHNICAL SERVICE BULLETIN
1) ADAPTOR CABLE FOR COMPRESSION PRESSURE RECORDER; 2) TEST CABLE WITH 16 AMPERE FUSE; MODELS 107, 124, 126 AND 201
Model(s): 1982 Mercedes-Benz 380 SLC; 1981-1983 Mercedes-Benz 380 SEL; 1981-1985 Mercedes-Benz 300 SD, 380 SL; 1982-1983 Mercedes-Benz 380 SEC; 1984-1985 Mercedes-Benz 380 SE, 500 SEC, 500 SEL; 1984-on Mercedes-Benz 190 D, 190 E; 1986-1987 Mercedes-Benz 300 SDL; 1986-on Mercedes-Benz 300 E, 420 SEL, 560 SEC, 560 SEL, 560 SL; 1987 Mercedes-Benz 300 D, 300 TD; 1987-on Mercedes-Benz 260 E; 1988-on Mercedes-Benz 300 CE, 300 SE, 300 SEL, 300 TE
Group: 15 - Engine Electrical System: Charging, Ignition, Preglow, Starter; 58 - Special Tools
Bulletin No.: 15/37, 58/68
Date: December 1988
1) ADAPTOR CABLE FOR COMPRESSION PRESSURE RECORDER
The adaptor cable is required to establish a good connection for the compression pressure recorder. It is to be connected between the compression pressure recorder and the starter connection (terminal 50) of the wiring harness. The use of this adaptor cable will prevent short circuits and/or faulty contacts which could cause the destruction of other electrical components.
To prepare the adaptor cable for use, the black alligator clip of the compression pressure recorder must be exchanged for the male single-pole connector supplied with the adaptor cable. To replace the alligator clip with the male single-pole connector, first cut off the alligator clip from the compression pressure recorder cable. Separate the plastic insulator from the single-pole connector by warming the plastic in hot water and pulling them apart with 2 pairs of pliers. Slip the insulator onto the wire of which the alligator clip was cut off. Solder that wire to the single-pole connector. Push the insulator over the pin connector.
On vehicles with screw-type cable connectors, the alligator clip of either the electrical connector kit 201 589 00 99 00 or of the accessory kit 201 589 00 99 24 must be connected between the starter connection (terminal 50) and the single-pole connector of the compression pressure recorder, instead of the adaptor cable.
2) TEST CABLE WITH 16 AMPERE FUSE
To prevent electrical shorts when bridging contacts during troubleshooting, e.g. fuel pump relay or pre-glow relay, a test cable with 16 Ampere fuse must be used. This test cable is to be used in conjunction with the electrical connector kit 201 589 00 99 00.
SPECIAL TOOL INFORMATION
| Tool Name | Tool Number | Group/Category |
|---|---|---|
| Adaptor cable with single-pole plug | 124 589 36 63 00 | A |
| Test cable with 16 Ampere fuse | 124 589 37 63 00 | B |