FixVault

Retrieving Codes

NOTE: Following procedures are performed using a impulse counter scan tool. Codes may also be retrieved using HHT. Follow HHT manufacturer's instructions to retrieve codes using HHT.
  1. Using Adapter (140 589 14 63 00), connect Impulse Counter (124 589 19 21 00) to data link connector, according to manufacturer's instructions. Turn ignition switch to ON position. Press start button for 3 seconds, wait 3 seconds and LED should flash. Count flashes to determine code and record code.
  2. After LED stops flashing, press start button for 3 seconds. After 3 seconds LED will flash. Count number of flashes to determine next code and record code.
  3. Repeat step 2) until first code is retrieved again. When first code is retrieved again, retrieval sequence is complete. After codes have been retrieved, perform appropriate test in SYSTEM TESTS  . See IMPULSE READOUT INDICATION  table.
NOTE: Codes 2-14 indicate which component caused anti-theft system to activate, not necessarily the presence of a malfunction or a defect.
IMPULSE READOUT INDICATION

Code Cause
1 No Problem Found
2 (1) Trunk Lid Circuit
3 (2) Engine Hood Circuit
5 (3) Center Console Compartment Circuit
6 (4) Right Door Switch Circuit
10 (5) Radio Circuit
12 (6) Ignition Circuit
14 (7) Stoplight Switch Circuit
19 (8) Anti-Theft Control Module
20 (9) Left Door Actuator (No Ground)
21 (10) Shorted Starter Lock-Out Relay Module (11) Or Shorted Anti-Theft Status Indicator Light
22 (12) Shorted Starter Lock-Out Relay Module (13) Or Open Circuit To Circuit No. 30 In Armed Status
23 (14) Open Circuit To Circuit No. 30 In Armed Status
(1) Perform TEST 7  under SYSTEM TESTS.
(2) Perform TEST 8  under SYSTEM TESTS.
(3) Perform TEST 13  under SYSTEM TESTS.
(4) Perform TEST 6  under SYSTEM TESTS.
(5) Perform TEST 10  under SYSTEM TESTS.
(6) Perform TEST 11  under SYSTEM TESTS.
(7) Perform TEST 9  under SYSTEM TESTS.
(8) Replace anti-theft control module.
(9) Perform TEST 12  under SYSTEM TESTS.
(10) Models with Temic control modules only. Perform TEST 20  .
(11) Models with Becker control modules only. Perform TEST 15  .
(12) Models with Becker control modules only. Perform TEST 20  .
(13) Models with Temic control modules only. Perform TEST 1  .
(14) Models with Becker control modules only. Perform TEST 1  .