FixVault

BAS Pressure Reduction Function

The BAS release switch (s1) is switched passively. Solenoid valve (y1) is switched off and only creates sufficient brake pressure to correspond to the position of the brake pedal.

Fig 1: BAS Pressure Reduction Function
G00221834Courtesy of MERCEDES-BENZ OF NORTH AMERICA.