Ventilation, function - GF83.10-P-2000GH
MODEL 163 up to 31.8.01
Function
The ventilation system ensures:
- that the windshield and windows are kept without mist.
- there is a supply of fresh air to the vehicle occupants.
- that constant and pleasant temperatures are quickly achieved in the vehicle interior.
Ventilation is achieved with the assistance of the blower motor (M2) during normal operation, when vehicle is stationary or to increase the air quantity.
Fresh air is drawn into the heater housing via the air inlet. Depending on the control module setting, the air is directed through the air ducts to the air vents in the interior.
The air flows out of the vehicle again through the rear vent via ventilation slots to the left and right in the area below the rear side windows.
In recirculating air mode, air is drawn out of the interior of the vehicle through the recirculating air flap by the blower motor (M2), and passed to the heater housing.
| Air inlet, location/function | GF83.10-P-2138GC | ||
| Air ducts, location/task/design | GF83.10-P-2139GH | ||
| Rear vent, location/task/function | GF83.10-P-2143GC | ||
| Defroster vent, location/task/function | GF83.10-P-2144GC | ||
| Center nozzle, location/task/function | GF83.10-P-2149GC | ||
| Lateral nozzle, location/task/function | GF83.10-P-2150GC | ||
| Front footwell air outlet, location/task/function | GF83.10-P-2145GC | ||
| Rear footwell air outlet, location/task/function | GF83.10-P-2146GC | ||
| Blower, location / task / design / function | GF83.10-P-2102GC | ||
| Series resistor group, location/task/function | GF83.10-P-2161GC | ||
| Dust filter, location / task / function | GF83.10-P-2142GH | ||
| Fresh air/recirculation flap, location / task / function | GF83.20-P-2111GC | ||
| Recirculating air switch, location/task/design/ function | GF83.10-P-2117GH | ||
| Fresh air/recirculation flap actuator motor, location / task / function | GF83.30-P-2116GC | ||
| Blower switch, location/task/design/function | GF83.25-P-2100GC | ||
| Air distribution switch, location/task/design/ function | GF83.25-P-2101GH | ||
| Heater housing position/task/function | GF83.20-P-2110GC | ||
| Evaporator housing, location/task/function | GF83.30-P-2119GH |