O2 sensor design - GF07.04-P-4103-03GC

Planar sensor 

Fig 1: Identifying O2 Sensor Design Components - Planar Sensor
G04736507

Voltage-free insulated O2 sensors are used.

The active sensor ceramic consists of a gas-permeable ceramic body manufactured from zirconium dioxide. A protective tube with several slots protects the ceramic body from mechanical stresses and from temperature jumps.

The power output of the sensor heater at operating temperature is 18 W, 12 W or 7 W.

Electrical connection through 4-pin connector.