Heated seats switch-off function - GF91.30-P-2001PQ

MODELS 203.0 /2 /7 as of 24.4.04 with CODE (873) Electrically heated left and right front seats 

Function prerequisites: 

Automatic shut-off of heated seats (HS) via timer control 

The upper control panel control unit (N72/1) implements the timer control for the heated seats (HS).

IMPORTANT The heating time for heating stage 1 can be programmed using the diagnosis facility.

Manual heated seats (HS) shut-off 

Operate left front HS switch (N72/1s10) and right front HS switch (N72/1s11) until the respective LEDs in the left front HS switch (N72/1s10) and the right front HS switch (N72/1s11) go off.

The heated seats (HS) are also switched off depending on the following criteria, which are listed in descending priority order: 

In order to prevent the heated seats from being switched on if a plug falls out or a heated seats (HS) cable is sheared off, the resistance value at the driver level output is checked at frequent intervals. If the resistance value is too high the left front HS switch (N72/1s10) and the right front HS switch (N72/1s11) are no longer inquired by the upper control panel control unit (N72/1).

If the upper control panel control unit (N72/1) receives the information "interior temperature > 40°C":

the heated seats (HS) are shut off.

When the ignition is switched off, the heated seats (HS) are also switched off. However, the timer control continues to run for a further 5 minutes as long as circuit 15C is on.

If terminal or terminal 15 is switched now on again, the active stage is also switched on again in accordance with the timer control setting after a 2-second delay.

If the undervoltage threshold of 11 V is exceeded for longer than 3 seconds the heated seats (HS) are shut off (timer control continues to run).

If undervoltage is detected the active LED's in the left front HS switch (N72/1s10) and the right front HS switch (N72/1s11) flash at a frequency of approximately 1.5 Hz and brightness of 50%. The heated seats cannot be switched on again until a permissible voltage of 11.5 V has been present for longer than 3 seconds.

The heated seats (HS) become active again if the overvoltage threshold of 16 V is exceeded. The active LEDs in the left front HS switch (N72/1s10) and the right front HS switch (N72/1s11) are no longer powered to prevent a fault from occurring.

The heated seats (HS) are switched off during the starting procedure (timer control continues to run). After starting has taken place the heated seats (HS) are switched on again after a 2-second delay.