The fan control function engine 272 - GF07.61-P-3023V

ENGINE 272.942 in MODEL 171 

ENGINE 272.963 in MODEL 171 

Shown on engine 272.963 in model 171 

Fig 1: Fan Control Function (Shown On Engine 272.963 In Model 171)
G04738376Courtesy of MERCEDES-BENZ USA

The ME-SFI [ME] control unit indirectly actuates the electric suction fan engine and AC with integrated control infinitely.

The fan specified speed is transmitted by the ME control unit via a pulse width modulated signal (PWM signal).

The on/off ratio is 10 to 90%.

Meaning:

10% Electric suction fan OFF

20% Electric suction fan "ON", minimum speed

The status of the automatic air conditioning is transmitted from the instrument cluster via the CAN data bus to the ME-SFI [ME] control unit. The fan specified speed is dependent on this information and on the coolant temperature.

The suction fan continues running for up to 5 minutes after ignition "OFF" if the coolant temperature, the engine oil temperature (from the temperature model) or the temperature of the ME control unit exceeds specified maximum values.

If the battery voltage drops excessively during this operation, suction fan run-on is suppressed.

20% Electric suction fan "ON", minimum speed

90% Electric suction fan "ON", maximum speed.

IMPORTANT If the actuation is faulty, the electric suction fan rotates with maximum rotational speed (fan emergency mode).

If the battery voltage drops excessively during this operation, suction fan run-on is suppressed.

Component description for the ME-SFI [ME] control unit GF07.61-P-6000V 
Component description for the crankshaft Hall sensor GF07.04-P-6220V 
Component description for the coolant temperature sensor GF07.04-P-6040V