Heated seats switch-over function - GF91.30-P-2002Q

MODEL 209.3 up to 1.6.03 with CODE (873) Electrically heated left and right front seats 

Function requirement: 

Manual switchover 

Pressing the left front HS/seat ventilation switch (N72/1s10) or the right front HS/seat ventilation switch (N72/1s11) once enables you to manually:

The upper control panel control module (N72/1) correspondingly reduces or increases the electric power output for the left front seat heated cushion (R13/1) and left front backrest heated cushion (R13/2) or the right front seat heated cushion (R13/3) and right front backrest heated cushion (R13/4). Switchover is indicated by illumination of one or both LEDs in the left front HS/seat ventilation switch (N72/1s10) or right front HS/seat ventilation switch (N72/1s11).

Automatic switchover in heating stage 1 after expiry of heating-up time (timer control) 

The upper control panel control module (N72/1) implements the timer control for the heated seats.

If the maximum heating-up time of 5 min. is reached, the upper control panel control module (N72/1) automatically initiates the changeover from heating stage 2 to heating stage 1 to reduce the power consumption. The upper control panel control module (N72/1) reduces the electric power output for the left front seat heated cushion (R13/1) and left front backrest heated cushion (R13/2) or the right front seat heated cushion (R13/3) and right front backrest heated cushion (R13/4) and switches off the second LED in the left front HS/seat ventilation switch (N72/1s10) or right front HS/seat ventilation switch (N72/1s11). After another 30 min. heating time the heated seats are switched off.

IMPORTANT The heating times can be programmed via the diagnosis; the times listed in the table are ex-factory settings.

Operating condition Heating duty cycle Function display
Heating stage 1 Heating stage 1 (Heating duration 30 min. after switch on or switchover, then heated seats OFF) 33% 1 red LED
Heating stage 2 Heating stage 2 (Heating duration 5 min. after switch on or switchover, then heating stage 1) Output driver at continuous operation 2 red LEDs
Automatic switchover Switchover from heating stage 2 to heating stage 1 after 5 min., then after 30 min. heated seats OFF Switchover output driver continuous operation after 33 % switchover from 2 LEDs red to 1 LED red
  Heated seat/seat ventilation switch, location/ design/function   GF91.30-P-3007Q 
  Electronic ignition/starter switch control module, location/purpose   GF80.57-P-4120Q
  Upper control panel control module, location/ task/design/function   GF54.21-P-4105Q