Switch on/off behavior, function - GF82.85-P-2006TA

MODEL 211.0/2 up to 31.5.06 with CODE (527) Navigation module for COMAND 

When the driver door is opened, the navigation processor (N41/1) is activated automatically, first via the Controller Area Network bus class B (interior) (CAN-B) and then via the Media Oriented System Transport (MOST) ring. This procedure takes approximately t = 2 seconds and may be accompanied by barely audible noise from the CD-ROM drive integrated in the navigation processor (N41/1). The display of the COMAND operating, display and control unit (A40/3) remains switched off. If no status change in "Circ.15C" or "Circ. 15R ON" occurs at the electronic ignition switch control unit (N73), the navigation processor (N41/1) remains activated for t = 30 min. This is followed by an automatic cutout.

Activating the overall system 

Position 1: 

When the transmitter key (A8/1) is inserted in the electronic ignition switch control unit (N73), i.e. "Circ. 15C ON".

In this position, only the bus systems are activated for t = 3 min in order to speed up the switch-on procedure.

If the COMAND operating, display and control unit (A40/3) is switched on using the "ON button (ON/OFF)", the automatic shut-off occurs after t = 30 min.

Position 2: 

Turning the transmitter key (A8/1) in the electronic ignition switch control unit (N73) to position 1 "Circ. 15R ON" switches the COMAND operating, display and control unit (A40/3) on, provided that it was on before the transmitter key (A8/1) was last removed. It remains in operation until the transmitter key (A8/1) is removed again.

The function options are restricted to:

Position 3: 

Turning the transmitter key (A8/1) further in the electronic ignition switch control unit (N73) to position 2 "Circ. 15 ON" makes all the functions in the vehicle operational. The system which was active before it was last switched off (e.g. radio) is switched on and the corresponding basic menu is displayed. If the COMAND operating, display and control unit (A40/3) was switched off for longer than t = 30 minutes, a warning menu with general information on the use of the system appears.

Position 4: 

The engine is started by turning the transmitter key (A8/1) in the EIS control unit (N73) to position 3, "circuit 15X ON".

If a considerable voltage drop occurs during the engine start, the system switches itself off for this time and is switched on again when the on-board electrical system has stabilized.

Characteristics when operating the ON/OFF button 

The COMAND operating, display and control unit (A40/3) can also be switched on with the transmitter key (A8/1) removed by pressing the "ON button (ON/OFF)" on the rotary switch. All MOST functions are then available for 30 minutes. The system switches off automatically once 30 minutes have elapsed. If a shut-off has taken place after t = 30 min, the system can be switched on again by pressing the "ON button (ON/OFF)". The cycle of 30 minutes then starts from the beginning.

Switching-off characteristics via AUTO-ON 

The COMAND operating, display and control unit (A40/3) switches to the "AUTO-ON" function state if it has been "awakened" by a MOST subscriber (e.g. telephone call or SMS).

In this case the function status that the system was in prior to the wake-up is stored. When the functions or user instructions that were initiated by the wake-up have completed, the system status prior to the arrival of the wake-up signal is reinstated. The COMAND operating, display and control unit (A40/3) does not accept display requests from the other MOST subscribers in the "AUTO-ON" function status, nor does it awake these subscribers. Switching off takes place either via the "ON button (ON/OFF)" or by removing the transmitter key "Circ. 15C OFF".

An active phone call is not interrupted by removing the transmitter key (A8/1). In this case the MOST will switch itself off.

Switch off characteristics 

The COMAND operating, display and control unit (A40/3) is switched off using the "ON button (ON/OFF)" or by removing the transmitter key (A8/1) from the electronic ignition switch control unit (N73) "Circ. 15C OFF".

When the MOST is shut down, the defined navigation system after-run time of t = 30 min starts (standby mode). During this period all the important locating parameters are stored. Furthermore, the COMAND operating, display and control unit (A40/3) and audio gateway control unit (N93/1) are always in standby mode when CAN-B (interior) is active.

Switch off characteristics at undervoltage 

The central computer of the COMAND operating, display and control unit (A40/3) constantly monitors battery voltage. Depending on the voltage value the system will act as follows:

The battery voltage is 9.5 to 11.5 V (battery warning range):

Battery voltage below 9.5 V (undervoltage)

Procedure for switching on and off in vehicles with code (889) Keyless Go 

If the vehicle is started or stopped using the Keyless Go system, the procedure for switching on and off is identical with the procedure for restarting using the transmitter key (A8/1) "Circ. 15 ON/OFF".

Volume/tone adjustments, function GF82.60-P-2003TA