Blower function - GF83.10-P-2102-02PC
Operation
The comfort AAC control and operating module C-AAC (N22/7) sends a control voltage of 0 - 100 % over the AC bus to the blower regulator (A32n1). This regulates the operating voltage for the blower motor (A32m1) depending on the control voltage applied from 0 to 100 %.
This facilitates control of the blower motor speed from 0 - 100 %. The blower motor regulator (operating voltage) is influenced by the following factors:
- blower motor output setting (AUTO/manual)
- Control functions (EC or AC OFF, REST (residual engine heat utilization), air distribution duct)
- Mode status (heating, cooling)
- Intensity of sun
- Coolant temperature
- Vehicle speed
- Fresh air/recirculation flap setting
- Position of activated carbon filter flap
- Flap positions
- Circuit 15 (blower motor (A32m1) ON), starter running (blower motor (A32m1) OFF)
The blower motor output can be increased in relation to outside temperature.
In order to ensure that the windows are not fogged up when outside temperatures are low and the passenger compartment temperature level doesn't drop, the blower motor output is increased at outside temperatures of -10 °C to -15 °C by a maximum of 15 %.