FixVault

Blower regulator function - GF83.10-P-2103-01P

WARNING: This page does not describe the selected car, but rather 25 other vehicles, including the 2007 Mercedes-Benz C350, 2007 Mercedes-Benz C280, 2007 Mercedes-Benz C230, 2006 Mercedes-Benz C55, and 2006 Mercedes-Benz C350. However, it is still accessible from the selected car via links, so may be relevant.

Operation for automatic heater (HEAT) and automatic air conditioning (AAC) 

In automatic heating mode (HEAT) and automatic air conditioning (AAC) the blower controller, in manual operation, is actuated in 6 stages via the blower switch integrated in the control and actuating unit for automatic heating and automatic air conditioning systems as well as via the air conditioning Bus.

In addition, the automatic operating mode of the automatic air conditioning (AAC) can be selected via the AUTO button (AUTO BUTTON ).

Depending on the actually measured interior space temperature and the set specified temperature, the blower controller then controls the operating voltage for the blower (0 - 100%). This results in control of the blower speed between 0 - 100%.

Function for Automatic comfort air conditioning (C-AAC) 

By operating the blower button (OFF (NO AIR SUPPLY)MINIMUM AIR VOLUME ), a control voltage (0 - 100%) is transmitted to the blower controller via the control and actuating unit of the automatic air conditioning system and the air conditioning Bus. Depending on the existing control voltage, the blower controller then controls the operating voltage for the blower between 0 - 100%. This results in control of the blower speed between 0 - 100%.

In addition, the automatic operating mode can be selected via the AUTO button

(AUTO BUTTON ).

Depending on the actually measured interior space temperature and the set specified temperature, the blower controller then controls the operating voltage for the blower (0 - 100%). This results in control of the blower speed between 0 - 100%.

IMPORTANT The blower controller can be diagnosed in all three systems. The following values can be called up:

Automatic heater (HEAT) and automatic air conditioning (AAC)

Blower switch setting Control voltage, blower controller
Stage 0 0 %
Stage 1 16 %
Stage 2 28 %
Stage 3 43 %
Stage 4 54 %
Stage 5 70 %
Stage 6 100 %
Automatic comfort air conditioning (C-AAC)

Selected blower stage (Indication in display) Control voltage, blower controller
No segment 0 %
Segment 1 16 %
Segment 2 20 %
Segment 3 30 %
Segment 4 46 %
Segment 5 64 %
Segment 6 80 %
Segment 7 100 %