FixVault

ME-SFI start quantity control function - GF07.61-P-3010AM

ENGINE 113.990 in MODEL 211, 219 

ENGINE 113.991 in MODEL 215, 220 

ENGINE 113.992 in MODEL 230 up to Model Year 2008 

ENGINE 113.993 in MODEL 463 up to 31.5.12 

ENGINE 113.995 in MODEL 230 up to Model Year 2008 

Fig 1: Identifying ME-SFI Start Quantity Control Function Diagram
G07870939Courtesy of MERCEDES-BENZ USA

To facilitate starting a cold engine, additional fuel must be injected during the starting procedure (depending on the coolant temperature). The increased quantity of fuel injected is achieved by extending the injection time.

The start quantity control is dependent on:

The start quantity control is enabled after start recognition. It remains activated until a temperature-related engine speed is exceeded.

The higher the coolant temperature, the lower is the start quantity enable by the ME-SFI control unit.

  Fuel injection valve, location/task/design/function   GF07.03-P-5004KE
  Crankshaft position sensor, location/task/design/function   GF07.04-P-4116AM
  Coolant temperature sensor, location/task/design/function   GF07.04-P-5026AM
  ME-SFI control unit, location/task/design/function   GF07.61-P-5000AM
  Throttle valve actuator, location/task/design/function   GF30.22-P-4101AM