FixVault

Control valve pressure, function - GF27.60-P-3017GZ

TRANSMISSION 722.9 in MODEL 164.1 /8, 216, 221, 251.0 /1 up to Model Year 8 

The control valve supply pressure is derived from the working pressure and is limited to a maximum pressure of 8 bar. 2 supply pressure regulating valves are used. Supply pressure regulating valve 1 supplies the following control solenoid valves:

Supply pressure regulating valve 2 supplies the following control solenoid valves:

By using the supply pressure 1 regulating valve and supply pressure 2 regulating valve the control solenoid valve groups are isolated from each other and when there is no shift (via a gear) there is a reciprocal influencing of control solenoid valve groups.

  Control solenoid valve component description Working pressure control solenoid valve GF27.19-P-5147GA 
Clutch control solenoid valve K1 GF27.19-P-5147GB 
Clutch control solenoid valve K2 GF27.19-P-5147GC 
Clutch control solenoid valve K3 GF27.19-P-5147GD 
Brake control solenoid valve B1 GF27.19-P-5147GE 
Brake control solenoid valve B2 GF27.19-P-5147GF 
Brake control solenoid valve B3 GF27.19-P-5147GG 
Torque converter lockup clutch control solenoid valve GF27.19-P-5147GH 
  Oil pump component description   GF27.57-P-1010GZ