FixVault

Med 40 (Engine 270)

MODE $6 MED 40 (ENGINE 270)

Monitor ID Test ID Unit ID Unit Description
1 83 5   Exhaust Gas Sensor Monitor Bank 1 - Sensor 1
1 84 5   Exhaust Gas Sensor Monitor Bank 1 - Sensor 1
1 8A 85   Exhaust Gas Sensor Monitor Bank 1 - Sensor 1
2 5 10 s Exhaust Gas Sensor Monitor Bank 1 - Sensor 2
2 6 10 s Exhaust Gas Sensor Monitor Bank 1 - Sensor 2
2 81 10 s Exhaust Gas Sensor Monitor Bank 1 - Sensor 2
2 82 10 s Exhaust Gas Sensor Monitor Bank 1 - Sensor 2
2 83 0A V Exhaust Gas Sensor Monitor Bank 1 - Sensor 2
2 84 0A V Exhaust Gas Sensor Monitor Bank 1 - Sensor 2
21 92 2F % Catalyst Monitor Bank 1
35 B8 9C ° Monitor Bank 1
35 B9 9C ° Monitor Bank 1
35 BA 9C ° Monitor Bank 1
35 BB 9C ° Monitor Bank 1
39 A7 FE Pa EVAP Monitor (Cap Off, 0.150")
3B A4 FE Pa EVAP Monitor (0.040")
3C A6 FE Pa EVAP Monitor (0.020")
3D B4 FE Pa Purge Flow Monitor
3D B1 FE Pa Purge Flow Monitor
3D B3 17 kPa Purge Flow Monitor
41 C1 16 °C Exhaust Gas Sensor Heater Monitor Bank 1 - Sensor 1
42 C1 14 kOhm Exhaust Gas Sensor Heater Monitor Bank 1 - Sensor 2
A2 0B 24 counts Misfire Cylinder 1 Data
A2 0C 24 counts Misfire Cylinder 1 Data
A3 0B 24 counts Misfire Cylinder 2 Data
A3 0C 24 counts Misfire Cylinder 2 Data
A4 0B 24 counts Misfire Cylinder 3 Data
A4 0C 24 counts Misfire Cylinder 3 Data
A5 0B 24 counts Misfire Cylinder 4 Data
A5 0C 24 counts Misfire Cylinder 4 Data