Publication date: 2013-10-30
Reference number: 54.21/260

PROGRAMMING OF CONTROL UNITS

PROGRAMMING OF CONTROL UNITS

TECHNICAL SERVICE BULLETIN

Reference Number(s): P-B-54.21/260, Date of Issue:  October 30, 2013
MERCEDES-BENZ: MY-All, Model 212.095/098/195/298
GROUP: 54 - Electrical system, equipment and instruments

SUBJECT

MY-All, Model 212.095/098/195/298 

Programming of Control Units 

Please note that the state of charge (SOC) of the high-voltage battery must be checked before every control unit programming procedure. The SOC value must be read from the instrument cluster or COMAND (under hybrid functions).

If the SOC shows a value < 50 %, the high-voltage battery must be recharged (charging when stationary). Follow the instruction in Charge High-Voltage Battery document AR54.10-P-1170EH (operation step 5.1).

The high-voltage battery must be charged to a state of charge of 75 % SOC before a control unit is programmed with Xentry Diagnostics. If the SOC is between 5 % and 10 %, the HV contactors of the high-voltage battery must be closed manually.

Please note that there are two different procedures depending on which XENTRY DAS version is used. In both cases, a password must be requested from the SDS HelpDesk.

Valid for XENTRY DAS Version 9/20/2013 

Carry out menu item "Manually close contactors" (battery management system control unit N82/2 (BMS)). The high-voltage battery must be charged to a state of charge of 75 % SOC analogous to the document AR54.10-P-1170EH operation step 5.1.

Valid for XENTRY DAS Version 11/2013 

The high-voltage battery must be charged to a state of charge of 75 % SOC analogous to Charge High-Voltage Battery AR54.10-P-1170EH operation steps 4 and 5.1.

If the SOC is < 5 %, the high-voltage battery can no longer continue to be used and must be replaced (see Charge High-Voltage Battery AR54.10-P-1170EH operation step 6).