Remove instrument panel pad and visually determine which direction to rotate sensor calibration locking pin. See Fig 1. While moving temperature control lever, rotate calibration locking pin into notch of control arm. Control lever should now be at "75". if not, loosen cable retaining screw and move lever to "75". Be sure calibration pin remains in notch. Tighten cable retaining screw and check operation.