FixVault

Manual Lever Position (MLP) Sensor

MLP SENSOR SPECIFICATIONS

Position (1) Volts (1) Ohms
P 4.41 4160
R 3.60 1440
N 2.83 733
D 2.09 401
2 1.37 211
1 0.68 81
(1) Values may differ by as much as 15 percent.