FixVault

Hydraulic System Bleeding

  1. Disconnect coil wire. Fill reservoir. Raise and support vehicle. Crank engine with starter until fluid level remains constant. Avoid overheating starter. Refill reservoir.
  2. Reconnect coil wire. Start engine and allow it to run several minutes. Turn steering from stop to stop. Stop engine. Check fluid level and add fluid as necessary.