Check Hydraulic Actuator Assembly Ground
With ignition switch in OFF position, measure resistance of Black wire between screw terminal on right side of hydraulic actuator and ground. If resistance is less than 5 ohms, go to PINPOINT TEST C6 . If resistance is more than 5 ohms, service Black wire.