Connecting Rod - Bend

  1. Measure the connecting rod bend on a suitable alignment fixture. Follow the instructions of the fixture manufacturer. Verify the bend measurement is within specification.
    • For additional information, refer to SPECIFICATIONS .
    • If out of specification, install new components as necessary. Refer to 3.3L V6 for the procedure.
      Fig 1: Measuring Connecting Rod Bend
      G03411233Courtesy of FORD MOTOR CO.