FixVault

Generator Specifications: 2002

WARNING: This page is about a different car, the 2003 Mercury Mountaineer, 2003 Ford Explorer, 2002 Mercury Mountaineer, and 2002 Ford Explorer. However, it is still accessible from the selected car via links, so may be relevant.
GENERATOR SPECIFICATIONS - 2002

Application Maximum Amperage Output Rating
Generator Amperage Rating
Standard 95 Amp
58/120 65 Amp
45/110 60 Amp
35/90 45 Amp
Load Test (1)
With Tester Load (2) 58 Amps Or More
Without Tester Load (3) (4)
No-Load Test (1)(2) 13-15 Volts
(1) All tests are performed with engine running at 2000 RPM.
(2) All accessories off.
(3) Perform this test with engine running, A/C on, blower motor on high speed, and headlamps on high beam.
(4) With accessories on, voltage should increase a minimum of 0.5 volt above base voltage.