Transmission Range (TR) Sensor: Assembly

  1. Install the manual control valve into the housing and connect the transaxle range sensor. Make sure that the tab on the manual valve is correctly seated into the transaxle range sensor.
    • Tighten to 5 N.m (44 lb-in).
    Fig 1: Locating Transaxle Range Sensor Bolts
    G04656726Courtesy of FORD MOTOR CO.