SMART JUNCTION BOX (SJB) DIAGNOSTIC TROUBLE CODE (DTC) LIST

DTC Description Perform Test
B1486 Brake Pedal Input Circuit Ground Short Go to Pinpoint Test I .
B2044 Left Rear Stop Lamp Circuit Short to Ground For Freestyle or Five Hundred, go to Pinpoint Test J .
For Montego, REFER to Turn Signal and Hazard Lamps to continue diagnosis of the turn lamp.
B2045 Left Rear Stop Lamp Circuit Open For Freestyle or Five Hundred, go to Pinpoint Test J .
For Montego, REFER to Turn Signal and Hazard Lamps to continue diagnosis of the turn lamp.
B2046 Right Rear Stop Lamp Circuit Short to Ground For Freestyle or Five Hundred, go to Pinpoint Test J .
For Montego, REFER to Turn Signal and Hazard Lamps to continue diagnosis of the turn lamp.
B2047 Right Rear Stop Lamp Circuit Open For Freestyle or Five Hundred, go to Pinpoint Test J .
For Montego, REFER to Turn Signal and Hazard Lamps to continue diagnosis of the turn lamp.