Test precondition: 

Independent parking heater not in heating mode or after-running mode.

Wires from heater control unit to independent parking heater control unit O.K.

Instruction: 

Switch on independent parking heater via MID or on-board monitor.

FAULT 07 OVERHEATING PROTECTION TROUBLESHOOTING

Question Measure
Is battery voltage applied at connector strip plug connector X01017 between Pin 9 and vehicle ground? No Refer to Diagnosis Program.
(Wire from heater control unit to independent parking heater or heating control unit defective)
Yes OK
Is battery voltage applied at connector strip plug connector X01017 between Pin 7 and vehicle ground? No Overheating protection is active.
In this case, check:
Bleeding coolant system, refer to 64 12... FLUSHING COOLING SYSTEM WHEN REPLACING LATENT HEAT ACCUMULATOR DUE TO SALT LEAKS 
Temperature sensor, refer to FAULT 05 TEMPERATURE SENSOR 
Circulation pump, refer to FAULT 04 CIRCULATION PUMP  (and layout of water hoses (kink)
Yes Overheating protection is not active.