Functional Description (F57)
›
Cell Supervision Circuit
›
Nominal values
Nominal values
Observe the following setpoint values for the cell supervision circuit:
Variable
Value
Number
of battery cells 96
Number of cell blocks
8
Nominal voltage of one battery cell
3, 75 Volts
Nominal capacity of one battery cell
60 Ah