FixVault

Replacement: Encode the DME control unit

Encode/program control unit(s) 

Precondition 

The control unit was replaced.

NOTE: TECHNICAL INFORMATION 
Use the most recent software version to prevent faults during programming/coding.
The battery voltage must not fall below 13.0 V during programming.
Use only chargers for a low volt-vehicle electrical system that are recommended by BMW.
NOTE: TECHNICAL INFORMATION 
No high-voltage switch off is required in electric vehicles or hybrid vehicles for programming/coding.
The high-voltage system will be automatically switched off by the programming system.
Exception: 
BMW 101: Note Product and Measures Management Aftersales measure 55176388.