FixVault

Service Specifications

WARNING: This page is about a different car, the 2008 Mitsubishi Lancer. However, it is still accessible from the selected car via links, so may be relevant.
SERVICE SPECIFICATIONS

Item Standard value Limit
Regulated voltage (Ambient temperature at voltage regulator) --20°C (--4°F) 14.2 - 15.4 -
20°C (68°F) 13.9 - 14.9 -
60°C (140°F) 13.4 - 14.6 -
80°C (176°F) 13.1 - 14.5 -
Generator output line voltage drop (at 30 A) V - Maximum 0.3
Output current - 70 % of normal output current
Field coil resistance Ω Approximately 2 - 5 -
Brush protrusion length mm (in) - Minimum 2 (0.08)