Automatic Stop Check

  1. Connect 12 volts one terminal and ground other terminal. Disconnect jumper wires during operation to stop motor. See AUTOMATIC STOP OPERATION TERMINAL NUMBERS  for terminals and model application.
  2. Using a jumper wire, connect 2 terminals together. Connect 12 volts to other terminal and ground wiper motor bracket. Ensure motor runs, then stops. See JUMPER WIRE/BATTERY POSITIVE TERMINAL NUMBERS TABLE - REAR  . SeeFigure .
AUTOMATIC STOP OPERATION TERMINAL NUMBERS

Model Voltage (-) Terminal No. Voltage (+) Terminal No.
Cordia/Tredia 1 3
Mirage 4 1
Montero 3 1
Starion 4 3
Van/Wagon Ground 3
JUMPER WIRE/BATTERY POSITIVE TERMINAL NUMBERS - REAR

Model Jumper Wire Terminals No. Voltage (+) Terminal No.
Cordia/Tredia 1-2 3
Mirage 3-4 1
Montero 2-3 1
Starion (1) 1-4 3
Van/Wagon 2-3 1
(1) Connect negative side of battery to terminal No. 2.