FixVault

No Load Test

  1. Install starter in soft-jawed vise. Connect starter in series with a fully charged 12-volt battery. Connect a 100-amp ammeter and carbon pile rheostat in series with positive battery post and starter motor terminal. See Fig 1.
  2. Install voltmeter across starter motor. Adjust carbon pile rheostat to full resistance. Connect cable from starter motor body to negative battery terminal. Adjust carbon pile rheostat to proper test voltage. See STARTER NO LOAD SPECIFICATIONS  table.
  3. Note that maximum amperage is within specification and starter rotates smoothly. See STARTER NO LOAD SPECIFICATIONS  table.
STARTER NO LOAD SPECIFICATIONS

Application Test Voltage Maximum Amps @ Minimum RPM
Mirage
1.5L A/T 11.5 60 @ 6600
1.5L M/T 11.5 60 @ 6500
1.6L 11 90 @ 3000
Starion 11.5 100 @ 3000
Galant & Sigma 11 90 @ 3000
Montero 11 90 @ 3000
Pickup 2.0L
A/T 11 90 @ 3000
M/T 11.5 60 @ 6600
Pickup 2.6L 11 90 @ 3000
Precis
A/T 11.5 60 @ 6600
M/T 11.5 60 @ 6500
Van/Wagon 11 90 @ 3000
Fig 1: Starter No Load Test Connections
G90I08769Courtesy of CHRYSLER MOTORS.
CAUTION: Perform tests in less than 10 seconds to prevent coil damage.