Wastegate Actuator Test
Actuator is mounted on turbocharger. On M/T models, apply a pressure of 11.1 psi (.76 kg/cm2 ) to wastegate actuator to ensure actuator rod moves. On A/T models, apply a pressure of 10.4 psi (.72 kg/cm2 ). DO NOT apply more than 12.4 psi (.85 kg/cm2 ) to wastegate actuator or attempt to adjust wastegate valve.