FixVault

2.0L-VIN U

  1. Sensor is incorporated in airflow sensor assembly inside air filter housing. Disconnect airflow sensor connector. See Figure .
  2. Measure resistance between terminals No. 6 and 8 of airflow sensor connector (sensor side of connector). For specifications, see INTAKE AIR TEMP SENSOR RESISTANCE  table. Replace airflow sensor assembly if air temperature sensor resistance is not within specification.