Main Switch
- When switch is moved to Neutral position, continuity should be present between terminals No. 4 and 6. See Figure -Figure .
- When switch is moved to ON position, continuity should be present between terminals No. 2, 4 and 6. Connect battery voltage to terminal No. 2 and ground terminal No. 6.