Checking Automatic Stop

  1. Operate wiper motor at low speed. See CHECKING WIPER MOTOR OPERATION. Disconnect battery voltage to stop motor in any position except park.
  2. Using a jumper wire, connect terminals indicated. See AUTOMATIC STOP CHECK table. See Figure . Connect 12 volts to terminal indicated in table, and ground wiper motor bracket. Ensure motor parks wiper arm.
AUTOMATIC STOP CHECK

Model Jumper Wire Terminals No. Apply Voltage To Terminal No.
Precis 5 & 6 1
- Attach negative battery lead to terminal No. 3.