Code 128 - Closed Loop Temperature Not Reached
NOTE:
For component terminal identification, see TERMINAL IDENTIFICATION
in this article. For appropriate WIRING DIAGRAMS, see WIRING DIAGRAMS
section.
- Remove thermostat. Check that valve closes fully at room temperature. Place thermostat in container of hot water. Raise water temperature, check that thermostat begins to open at 195°F (90.5°C) and is fully open at 216°F (102°C). Valve lift is .31" (8 mm) from full closed to full open. If thermostat is within specification, go to next step. Replace thermostat if not within specification.
- Disconnect coolant temperature sensor connector. Measure resistance between sensor terminals. Resistance range is 9000-11,000 ohms at 77°F (25°C) to 600-800 ohms at 212°F (100°C). If sensor resistance is within specification, go to next step. If sensor resistance is not within specification, replace temperature sensor.
- Check PCM connector, temperature sensor connector, junction connector and wiring harness between PCM and coolant temperature sensor. If wiring and connectors are okay, replace PCM.