FixVault

Fluid Replacement

CAUTION: DO NOT crank engine for more than 15-20 seconds at a time.
  1. Remove reservoir cap. Disconnect return hose at reservoir. Drain fluid. Disconnect coil high tension wire. Raise and support vehicle.
  2. Turn steering wheel lock-to-lock several times while cranking engine to drain fluid from steering gear. Reconnect hose. Fill power steering system with fluid. Bleed system. See HYDRAULIC SYSTEM BLEEDING  .