FixVault

Without Scan Tool

  1. Move code registration switch on Remote Keyless Entry (RKE) control unit to SET I position. Press LOCK or UNLOCK button on transmitter. Move code registration switch on control unit to FIX position.
  2. Confirm that keyless entry system operates normally. If system does not operate normally, repeat step  1 . If 2 transmitters are used, register code on SET II position on RKE control unit and set in same manner as first transmitter.