FixVault

Inspection Procedure E-1: Keyless Entry System Does Not Operate

NOTE: To perform this test, MUT-II Scan Tool (MB991502), SWS Monitor Kit (MB991862) and Test Harness Set (MB991223) must be used.
CAUTION: To prevent damage to Scan Tool (MB991502), always turn the ignition switch to the LOCK (OFF) position before connecting or disconnecting scan tool.
  1. Check the central door locking system. Does the central door locking system work normally?
  2. Using the pulse check, check the input signal. See PULSE CHECK . Check input signals from the transmitter. Connect scan tool to the Data Link Connector (DLC). When the transmitter LOCK or UNLOCK switch is turned ON, check that scan tool sounds. When the transmitter LOCK or UNLOCK switch is turned ON, does scan tool sound?