FixVault

Door Switch

  1. Remove door switch. With door lock switch in relaxed position (door open), continuity should be present between all door switch terminals.
  2. With door lock switch in depressed position (door closed), no continuity should be present. If continuity between door switch terminals is not as specified, replace door switch.