< When using the MUT-II >

  1. Connect the MUT-II to the data link connector.
  2. Move the selector lever to P range.
  3. Start the engine.
  4. Turn the TCL switch to ON.
  5. Operate the MUT-II to start the actuator test (item No. 05) and fully depress the accelerator pedal at the same time. Check that the engine speed is kept down to 3,000 r/min at this time.
CAUTION: The actuator test should only be carried out for 3 seconds. Because the engine speed will increase once the actuator test is stopped, the accelerator pedal should be released quickly after it has been depressed.
NOTE: The TCL-ECU will output a "request torque: O" signal to the engine-ECU for 3 seconds while the actuator test is being carried out, and the TCL OFF indicator will illuminate during this time.