FixVault

Fuel Tank Differential Pressure Sensor Check

  1. Disconnect the fuel tank differential pressure sensor connector and connect special tool MB991348 between the terminals of the disconnected connector.
    Fig 1: Connecting Special Tool Between Terminals Of Disconnected Connector
    G03303485Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  2. Turn the ignition switch to "ON" and measure the output voltage between terminals 2 and 3.

    Standard value: 2.0 - 3.0 V