Power Window Relay Check

Fig 1: Checking Power Window Relay Terminals
G03507453Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
POWER WINDOW RELAY TERMINALS SPECIFIED CONDITION

BATTERY VOLTAGE TESTER CONNECTION SPECIFIED CONDITION
Not applied 4-5 Open circuit
  • Connect terminal No. 3 and the negative battery terminal.
  • Connect terminal No. 1 and the positive battery terminal.
4-5 Less than 2 ohms