Electric Remote Controlled Mirror Operation Check: Notes

Check that the mirror moves as described in the table when each terminal is connected to the battery.

Fig 1: Identifying Mirror Terminal
G03490484Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
BATTERY CONNECTION SPECIFICATIONS

BATTERY CONNECTION DIRECTION OPERATION
  • Connect terminal 1 to the negative battery terminal. Connect terminal 3 to the positive battery terminal.
Up
  • Connect terminal 3 to the negative battery terminal. Connect terminal 1 to the positive battery terminal.
Down
  • Connect terminal 1 to the negative battery terminal. Connect terminal 2 to the positive battery terminal.
Right
  • Connect terminal 2 to the negative battery terminal. Connect terminal 1 to the positive battery terminal.
Left